Healthy Homes Heating: What Size Heat Pump Does a Rental Need?

Sizing a heat pump to the heating standard

For Auckland landlords: get your kW figure from the Tenancy Services tool, match a heat pump to it and sort the wiring.

The Short Answer

What size heat pump does a rental need?

The right size is whatever the Tenancy Services heating assessment tool says your main living room needs, in kilowatts (kW). Your heat pump’s heating capacity has to meet or beat that figure. There’s no standard size for a rental, because the answer depends on the room, the insulation and where the house is. A small, well-insulated lounge might get by with a modest unit, while a big open-plan room in an older house can need a lot more. Run the tool first, then talk to us about the heat pump installation.

“The minimum heating capacity shows the heater(s) can heat and maintain the main living room to 18˚C.”

Tenancy Services, Healthy Homes heating guidance

The Rules

What the Healthy Homes heating standard asks for

The heating standard is one of the Healthy Homes rules for rentals. It covers one room: the main living room. That’s the largest room used for everyday living, such as the lounge, family room or dining room.

The room needs one or more fixed heaters that heat it directly. Portable heaters don’t count. Each heater must be at least 1.5 kW, and together they must meet the capacity the room needs. That capacity is set so the room can reach and hold 18 degrees.

Most landlords meet the standard with a heat pump. It has to have a thermostat, and almost every modern heat pump does. Open fires and unflued gas heaters aren’t allowed at all. Ducted systems can count, as long as the heat reaches the main living room directly through a vent or duct in that room.

There’s also a limit on plain electric heaters. Where the room needs over 2.4 kW, you can’t meet the standard with them. Heat pumps aren’t affected by this limit. Tenancy Services sets out the full rules.

Your Number

Use the heating assessment tool to get your number

Tenancy Services runs a free heating assessment tool, which calculates the minimum heating capacity for the main living room. You answer questions about the house, and it gives you a report with a figure in kW. Keep that report. It helps show the rental meets the standard.

Have these ready before you start:

  • Where the house is. The tool uses the council area to allow for the local climate. Colder places need more heat.
  • When the house was granted building consent. This tells the tool which building rules applied, so it can estimate the insulation. Your council can tell you, or it’ll be on a LIM report.
  • Measurements of the room. You’ll need the floor area and wall sizes, plus the size of any windows in outside walls.
  • What insulation there is. If you leave this blank, the tool guesses from the age of the house. If you’ve added insulation since the house was built, enter the actual figures. The required capacity often comes down.

One rule catches a lot of landlords out. Any space that’s always open to the lounge counts as part of it. That includes an open-plan kitchen, a hallway with no door or an open stairwell. If you can shut a door between the two spaces, you can leave the other space out.

Sloped or raked ceilings are another trap. The tool makes cautious guesses for these, so the result usually comes out higher than the room really needs. For a tricky layout, Tenancy Services suggests asking a professional to use the formula in the regulations instead.

CALL 021 770 696 OR CLICK TO CONTACT US

Choosing A Unit

Matching a heat pump to the number

Once you have the figure, look at the heat pump’s specifications. Every unit lists a heating capacity and a cooling capacity, both in kW. Use the heating figure, because that’s the one the standard cares about. Choose a unit whose heating capacity matches your number or is a bit above it.

Don’t be tempted to go much bigger. A unit that’s far too large costs more to buy and tends to switch on and off more often. It also won’t make the rental any more compliant than a correctly sized one.

Older Auckland houses often get a bigger figure than landlords expect. For a villa or bungalow, the tool bases its insulation guess on when the house was built. In an older house, that often means little or no wall insulation, so the figure goes up. Knocking the lounge and kitchen into one room raises it too, because the tool counts the whole open space. Run the tool before you look at units, not after.

Location matters too. The tool’s guide notes that some heat pumps struggle when it’s just above freezing outside. Most of Auckland is mild, but if the rental is somewhere colder, pick a unit that holds its output in cold weather.

Existing Heating

If the room already has a heater

You may not need to start from scratch. Existing heaters installed before 1 July 2019 can still count if they meet every condition below:

  • each heater is bigger than 2.4 kW
  • the heaters together reach at least 80 percent of the required capacity
  • each one is an acceptable type (no open fires or unflued gas heaters)
  • if the requirement is over 2.4 kW, none of them is a plain electric heater (heat pumps are fine).

If your older heat pump comes up a bit short, you can sometimes top up the capacity with another heater. Tenancy Services gives this example. The room needs 6.0 kW, and it has a 3.6 kW heat pump installed before July 2019. Adding a fixed 2.4 kW electric heater with a thermostat makes up the gap. This top-up is the one case where a small electric heater is allowed in a room that needs more than 2.4 kW.

That allowance ends when the old unit wears out. Its replacement has to meet the full required capacity on its own.

Power Supply

The electrical side

A heat pump that’s the right size still needs the right power supply. This is the part of the job that most often gets left to the last minute.

We wire each heat pump on a circuit of its own, sized to suit the unit. The circuit is protected by an RCD at the switchboard. An RCD is a safety switch that cuts the power if current leaks to earth. Outside, a lockable isolating switch goes on the wall near the outdoor unit. A technician can then turn the power off right there during servicing.

Before any of that, we make sure the switchboard has room. Older boards with ceramic fuses, or boards already full of circuits, often need work first. We explain how we check a switchboard before a heat pump goes in in a separate article.

Once the work is finished, we test the circuit and hand over a Certificate of Compliance. It shows the wiring meets New Zealand standards, so file it with your Healthy Homes paperwork.

Next Step

Getting a rental’s heating sorted

Run the heating assessment tool, note the kW figure, and get in touch. We’ll come and look at the living room and the switchboard, and work out where the outdoor unit should sit. You’ll then get a written quote covering the unit, the installation and the wiring.

Got your kW figure and want the heat pump sorted? We’re based in Waitākere and work right across Auckland. Use our contact form and include the figure from your report, or call 021 770 696.

Totally Amped Electrical, EWRB-registered electricians, Auckland

General information only: this article describes typical Auckland residential electrical work and the rules as they stood at publication, not advice specific to your property. Requirements change, so confirm the current position with a licensed electrician before starting any work.

HEALTHY HOMES HEAT PUMP FAQS

Does a heat pump meet the Healthy Homes heating standard?

Yes, if it’s fixed, has a thermostat and heats the main living room directly. It must also reach the figure the heating assessment tool gives for that room.

What happens if the heat pump is too big?

It still meets the standard, but you pay for capacity you don’t need. An oversized unit also tends to cycle on and off more, which is less comfortable and harder on the unit. Sizing it to the tool’s figure, or a little above, is the sensible choice.

How do I find out what size my current heat pump is?

Check the label on the indoor or outdoor unit, or look up the model number in the maker’s specifications. You want the rated heating capacity in kW, not the cooling figure. If you can’t find it, we can read the model off the unit for you.

Does ducted heating count for Healthy Homes?

Yes, if the heat gets to the main living room through its own vent or duct. The system’s output also needs to reach the required capacity.

Can an electrician do the Healthy Homes heating assessment?

No, not the specialist kind. Anyone can use the free heating assessment tool, including landlords themselves. The other option is an assessment by a qualified specialist, which the regulations define as an engineer or building scientist. We size and install the heat pump to the figure you get.